Configuration Procedure
Model names ending in “C” only: Run the BusLogic AutoSCSI configuration utility
and check the termination and that the Advanced option “BIOS Support for > 2
Drives (DOS 5.0 or above)” is set to No.
BT-757C only: If the system has a narrow target, turn off the “wide negotiation
option” when configuring devices.
Special Cases
Configuring Multiple Devices
Select an adapter model ending in “C” as the primary controller.
Choose an I/O address for the primary controller that precedes the secondary
controller in “Supported Settings”; for example, use an I/O address of 0x234 for
the primary controller, and make sure the secondary controller uses either 0x130
or 0x134.
Disable the BIOS on the secondary controller.
Wide-mode EISA adapters can support targets greater than 7 if the proper entries
are added to the system configuration files: /kernel/drv/sd (for disk) and
/kernel/drv/st.conf (for tape).
22
Device Reference Manual for Solaris 2.6 (Intel Platform Edition) April 1998