Chapter 7 Troubleshooting the System 167
5. Reconnect the target modem to the debug port on the target computer (or
restart the target computer in debug mode).
6. Use the host computer to dial into the target modem.
[Parity Error] Message
This message is displayed on the host computer if the baud rates are too high to
sustain a reliable connection. The following steps resolve this problem:
1. Force the baud rate of both modems to 9600 bps. Consult your modem
documentation for the initialization string(s) that sets the DTE and DCE rates
to 9600 bps. For U.S. Robotics modems, this command is AT&N6.
2. Add the /baudrate=9600 option to Boot.ini. This sets the baud rate on the
debug COM port to 9600 bps. Always set remote debug configurations for this
option.
3. Change the modem make and model on the target computer. If possible, use
the same make and model modem as the Citrix representative. Identical
modems appear to have a higher remote debug success rate versus modems
from different manufacturers.
5. Conduct a loopback test to isolate the network. Install the ICA Win32 Client
on the MetaFrame server and make an IPX connection back to the MetaFrame
server. If the loopback test passes, verify that ICA connections on the same
network segment as the MetaFrame server can connect. If clients on the same
network segment can connect but clients on other segments cannot connect,
there is a problem with the router configuration or cabling.
6. Install the most current ICA Client.
7. Install the most current network interface card (NIC) drivers on the client and
server machines.
8. Remove and reinstall the NWlink IPX service.
9. Use Event Viewer to check for connection-related error messages.
10. If the problem persists, create a debug trace for the ICA Client connection.