Adaptec SCSI RAID Software Reference Guide
container show failover
To display a list of failover disks assigned to an array, use the
container show failover
command. You assign failover disks
to an array with the
container set failover command.
Syntax
container show failover [{container}]
Parameters
{container}
Specifies the ID number (0 to 63) of the array whose assigned
failover disk(s) you want to display. If you do not specify this
parameter, the command displays all arrays and their assigned
failover disk(s).
Examples
The following example shows the failover disks assigned to array 0:
AAC0>container show failover 0
Executing: container show failover 0
container Scsi C:ID:L
--------- ----------------------------------
0 0:03:0 0:04:0
The example shows that array 0 was assigned disks 0:03:0 and 0:04:0
as failover disks.