container Commands
Table 5-7 displays the values for Write Cache Status:
Table 5-7. Values for Write Cache Status
Value Meaning
Active, not protected The status of the write cache for this array is as
follows:
■ Active – The write cache can accept write
operations from the array.
■ Not protected – The write cache is force-
enabled. Thus, the write cache accepts write
operations even if write data could be lost
due to no battery present or a bad battery on
the controller.
■ This status also indicates that the battery
status is OK.
Active, not protected,
battery low
The status of the write cache for this array is as
follows:
■ Active – The write cache can accept write
operations from the array.
■ Not protected – The write cache is force-
enabled. Thus, the write cache accepts write
operations even if write data could be lost
due to no battery present or a bad battery on
the controller.
■ This status also indicates that the battery
status is low.
Active, not protected,
battery not present
The status of the write cache for this array is as
follows:
■ Active – The write cache can accept write
operations from the array.
■ Not protected – The write cache is force-
enabled. Thus, the write cache accepts write
operations even if write data could be lost
due to no battery present or a bad battery on
the controller.
■ This status also indicates that the battery is
not present on the controller.