Adaptec 2120S - SCSI RAID Controller Guía de usuario Pagina 162

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 354
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 161
5-114
Adaptec SCSI RAID Software Reference Guide
Active, not protected,
battery reconditioning
The status of the write cache for this array is as
follows:
Active – The write cache can accept write
operations from the array.
Not protected – The write cache is force-
enabled. Thus, the write cache accepts write
operations even if write data could be lost
due to no battery present or a bad battery on
the controller.
This status also indicates that the battery is
being reconditioned.
Active, protected The status of the write cache for this array is as
follows:
Active – The write cache can accept write
operations from the array.
Protected – The write cache is enabled only
if a battery is present and its status is OK.
This status also indicates that the control-
ler’s battery is present and its status is OK.
Inactive, battery low The status of the write cache for this array is as
follows:
Inactive – The write cache cannot accept
write operations from the array.
Battery low – This controller’s battery
power is low.
Inactive, battery not
present
The status of the write cache for this array is as
follows:
Inactive – The write cache cannot accept
write operations from the array.
Battery not present – This controller has no
battery.
Inactive, battery
reconditioning
The status of the write cache for this array is as
follows:
Inactive – The write cache cannot accept
write operations from the array.
Battery low – The controller’s battery is
being reconditioned.
Table 5-7. Values for Write Cache Status (Continued)
Value Meaning
Vista de pagina 161
1 2 ... 157 158 159 160 161 162 163 164 165 166 167 ... 353 354

Comentarios a estos manuales

Sin comentarios