Adaptec 2110S - SCSI RAID Controller Guía de instalación Pagina 65

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 106
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 64
3-30
Adaptec RAID Installation Guide
9 To add a drive to a secondary controller, type
diskadd cCCbBBtTTdDD
For example, a new drive or array is connected to a secondary
Adaptec RAID controller on Channel A and the drive has a
TID 0. The controller number is 1 because it is a secondary
controller. Therefore, the command would be
diskadd c1b0t0d0
For details on
diskadd, refer to the diskadd(1M) man page.
FreeBSD
The Adaptec RAID controller driver is embedded in the kernel for
versions 4.1.1 and later. Therefore, you do not need to do anything
related to driver installation once your operating system is installed.
For the most up-to-date information on Adaptec’s support of
FreeBSD, or to download driver sources, visit
http://opensource.adaptec.com.
Caution: When adding a Zero Channel RAID (ZCR)
controller to an existing system, backup all data from
system drives prior to the installation. If the boot device is
connected to one of the onboard SCSI channels, the
operating system will need to be reinstalled after installing
the ZCR controller.
!
COMBINED RAID IG.BOOK Page 30 Tuesday, September 25, 2001 5:46 PM