GESTEK
Lab
Report No: 0712109V-01
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325
Accredited Lab. Of BSMI, NVLAP.
Page 23 of 31
Listed Lab. of Commerce, FCC, VCCI. NVLAP Lab Code:200085-0
Date of Test
February 21, 2008
Temperature 25 deg/C
EUT
Server
Humidity 68 %RH
Working Cond.
Mode 7
Display Pattern H Pattern
Antenna distance 10m at Vertical Frequency Range 30-1000MHz
Test Power Supply AC 100V/50Hz
No.
Frequency
MHz
Reading Level
dBµV
Factor
dB
Measurement
dBµV/m
Limit
dBµV/m
Over Limit
dB
Detector
1 50.0600 42.31 -13.71 28.60 40.00 -11.40 QP
2 249.9977 45.49 -9.60 35.89 47.00 -11.11 QP
3 480.1542 33.57 -4.13 29.44 47.00 -17.56 QP
4 499.9927 39.21 -3.71 35.50 47.00 -11.50 QP
5 640.0142 30.41 -1.26 29.15 47.00 -17.85 QP
6
★
666.6803
43.59 -0.96 42.63 47.00 -4.37 QP
7 720.0570 34.21 -0.28 33.93 47.00 -13.07 QP
8 725.4570 28.73 -0.19 28.54 47.00 -18.46 QP
9 800.0169 40.50 0.92 41.42 47.00 -5.58 QP
10 833.3835 39.62 1.35 40.97 47.00 -6.03 QP
11 866.8605 38.16 1.78 39.94 47.00 -7.06 QP
12 900.0187 30.31 2.20 32.51 47.00 -14.49 QP
Remarks:
1. All Readings below 1GHz are Quasi-Peak.
2. Measurement = Reading + Factor (Could have
±
0.01 tolerance due to computer automatically round off calculation).
3. Over Limit (Margin Value)=Measurement level-Limit value.
4. Factor = antenna factor + cable loss – amplifier gain.
5. “
★
” means that this data is the worse case measurement level.
6. The measurement uncertainty is 5.1 dB.
Remark: 1. The “Limit” in right-up corner in above diagram refers to Quasi-peak ; “Margin” refers to the data under 6dB.
Comentarios a estos manuales