Vista de pagina 19
GESTEK
Lab
Report No: 0712109V-01
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325
Accredited Lab. Of BSMI, NVLAP.
Page 18 of 31
Listed Lab. of Commerce, FCC, VCCI. NVLAP Lab Code:200085-0
Date of Test
February 25, 2008
Temperature
26
EUT
Server
Humidity
60 %
Test Mode
Mode 7 (Power 2)
Display Pattern
H Pattern
Test Power Supply
AC 100V/50Hz
Line
No.
Frequency
MHz
Reading Level
dBµV
Factor
dB
Measurement
dBµV
Limit
dBµV
Over Limit
dB
Detector
1
2.0229 25.81 9.64 35.45 73.00 -37.55 QP
2
2.0229 24.65 9.64 34.29 60.00 -25.71 AVG
3 2.8319 20.55 9.66 30.21 73.00 -42.79 QP
4 2.8319 20.52 9.66 30.18 60.00 -29.82 AVG
5 4.0252 18.66 9.65 28.31 73.00 -44.69 QP
6 4.0252 17.79 9.65 27.44 60.00 -32.56 AVG
7 8.1917 24.11 9.72 33.83 73.00 -39.17 QP
8 8.1917 21.71 9.72 31.43 60.00 -28.57 AVG
9 11.9476 24.56 9.79 34.35 73.00 -38.65 QP
10 11.9476 23.78 9.79 33.57 60.00 -26.43 AVG
11 13.3111 27.54 9.82 37.36 73.00 -35.64 QP
12
13.3111
25.29 9.82 35.11 60.00 -24.89 AVG
Remarks :
1. All readings are Quasi-peak and Average values.
2. Measurement = Reading + Factor (Could have
±
0.01 tolerance due to computer automatically round off calculation).
3. Over Limit (Margin Value)=Measurement level-Limit value.
4. Factor = L.I.S.N. insertion loss + cable loss
5. “
” means that this data is the worse case measurement level.
6. The measurement uncertainty is 3.6 dB.
Line
Remark: 1. The “Limit” in right-up corner in above diagram refers to Quasi-peak ; “AVG” refers to the limit of Average.