GESTEK
Lab
Report No: 0712109V-01
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325
Accredited Lab. Of BSMI, NVLAP.
Page 22 of 31
Listed Lab. of Commerce, FCC, VCCI. NVLAP Lab Code:200085-0
5.7 RADIATED EMISSIONS MEASUREMENT RESULTS
Date of Test February 21, 2008 Temperature 25 deg/C
EUT Server Humidity 68 %RH
Working Cond. Mode 7 Display Pattern H Pattern
Antenna distance 10m at Horizontal Frequency Range 30-1000MHz
Test Power Supply AC 100V/50Hz
No.
Frequency
MHz
Reading Level
dBµV
Factor
dB
Measurement
dBµV/m
Limit
dBµV/m
Over Limit
dB
Detector
1 49.3600 41.00 -13.77 27.23 40.00 -12.77 QP
2 249.9963 44.86 -9.60 35.26 47.00 -11.74 QP
3 480.0392 35.90 -4.14 31.76 47.00 -15.24 QP
4 499.9930 37.90 -3.71 34.19 47.00 -12.81 QP
5
★
666.6810
40.20 -0.96 39.24 47.00 -7.76 QP
6 720.0562 35.67 -0.28 35.39 47.00 -11.61 QP
7 725.0070 27.56 -0.20 27.36 47.00 -19.64 QP
8 750.0145 32.66 0.18 32.84 47.00 -14.16 QP
9 800.0163 37.50 0.92 38.42 47.00 -8.58 QP
10 833.3830 36.82 1.35 38.17 47.00 -8.83 QP
11 866.5782 28.34 1.78 30.12 47.00 -16.88 QP
12 900.0195 26.34 2.20 28.54 47.00 -18.46 QP
Remarks:
1. All Readings below 1GHz are Quasi-Peak.
2. Measurement = Reading + Factor (Could have
±
0.01 tolerance due to computer automatically round off calculation).
3. Over Limit (Margin Value)=Measurement level-Limit value.
4. Factor = antenna factor + cable loss – amplifier gain.
5. “
★
” means that this data is the worse case measurement level.
6. The measurement uncertainty is 5.1 dB.
Remark: 1. The “Limit” in right-up corner in above diagram refers to Quasi-peak ; “Margin” refers to the data under 6dB.
Comentarios a estos manuales