Report No: 0712109V-01
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325
Accredited Lab. Of BSMI, NVLAP.
Page 19 of 31
Listed Lab. of Commerce, FCC, VCCI. NVLAP Lab Code:200085-0
Date of Test
February 25, 2008
Temperature
26
℃
EUT
Server
Humidity
60 %
Test Mode
Mode 7 (Power 2)
Display Pattern
H Pattern
Test Power Supply
AC 100V/50Hz
Neutral
No.
Frequency
MHz
Reading Level
dBµV
Factor
dB
Measurement
dBµV
Limit
dBµV
Over Limit
dB
Detector
1
2.0222 31.97 9.64 41.61 73.00 -31.39 QP
2
★
2.0222
31.64 9.64 41.28 60.00 -18.72 AVG
3 2.8315 23.01 9.66 32.67 73.00 -40.33 QP
4 2.8315 22.58 9.66 32.24 60.00 -27.76 AVG
5 3.6420 22.43 9.65 32.08 73.00 -40.92 QP
6 3.6420 20.91 9.65 30.56 60.00 -29.44 AVG
7 8.1952 22.80 9.79 32.59 73.00 -40.41 QP
8 8.1952 19.58 9.79 29.37 60.00 -30.63 AVG
9 11.9486 25.37 9.85 35.22 73.00 -37.78 QP
10 11.9486 24.83 9.85 34.68 60.00 -25.32 AVG
11 13.3115 27.58 9.85 37.43 73.00 -35.57 QP
12 13.3115 25.35 9.85 35.20 60.00 -24.80 AVG
Remarks :
1. All readings are Quasi-peak and Average values.
2. Measurement = Reading + Factor (Could have
±
0.01 tolerance due to computer automatically round off calculation).
3. Over Limit (Margin Value)=Measurement level-Limit value.
4. Factor = L.I.S.N. insertion loss + cable loss
5. “
★
” means that this data is the worse case measurement level.
6. The measurement uncertainty is 3.6 dB.
Neutral
Remark: 1. The “Limit” in right-up corner in above diagram refers to Quasi-peak ; “AVG” refers to the limit of Average.