Adaptec SCSI RAID 2120S Guía de instalación Pagina 126

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 278
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 125
3-95
container Commands
container set failover
To assign an automatic failover disk(s) for a single array, use the
container set failover
command. If the array was already
assigned a failover disk(s), the command adds the specified disk(s)
to the array’s list of failover disk(s). Although all array types accept
failover assignments, only mirror set and RAID 5 array
(redundant) array types use the failover assignment if a disk fails.
Syntax
container set failover {container} {scsi_device}
[{scsi_device}...]
Parameters
{container}
Specifies the ID number (0 to 63) of the array on which to
assign an automatic failover disk(s).
{scsi_device}
Specifies the ID for the SCSI device that you want to assign as
a failover disk to the array specified in the
container
parameter. A SCSI ID consists of a SCSI channel number (for
example, 0, 1, 2, 3, etc.), a SCSI device ID (0 through 15
inclusive), and a SCSI device logical unit number (0 through 7
inclusive).
For further details, see scsi_device on page 1-10.
{scsi_device}...
Specifies the ID(s) for additional SCSI device(s) that you want
to assign as failover disk(s) to the array specified in the
container parameter.
Examples
Before assigning a SCSI device as a failover disk to an array, use the
container list
command to obtain information about any
existing arrays.
Vista de pagina 125