9-10
enclosure Commands
Specifically, the column can display the items listed in Table 9-2.
Table 9-2 Diagnostic Status
The EnclosureId, VendorId, and ProductId Columns
The EnclosureId column displays an identification number that is
unique for each enclosure management device product sold by a
particular manufacturer.
The VendorId column displays a string that identifies the
manufacturer of the enclosure management device. In the example,
the string that identifies the manufacturer of enclosure
management devices 0 and 1 is ESG-SHV.
The ProductId column displays a string that identifies the
enclosure management device’s product ID. In the example, the
product ID for enclosure management devices 0 and 1 is SCA
HSBP M2.
The Firmware Column
The Firmware column displays the current firmware revision of
the enclosure management device. In the example, the firmware
revision for enclosure management devices 0 and 1 is 0.14.
Related Commands
enclosure commands:
■ enclosure show fan (page 9-26)
■ enclosure show power (page 9-29)
■ enclosure show slot (page 9-32)
■ enclosure show status (page 9-36)
■ enclosure show temperature (page 9-41)
Status Meaning
PASSED No errors were detected and the diagnostic self-tests
were successful. This is the value displayed in the
example for both enclosure management devices.
FAILED Errors were detected and the diagnostic self-tests were
not successful.
UNKNOWN The status of the diagnostic self-tests is unknown.
Comentarios a estos manuales