3-114
container Commands
container unmirror
To unmirror a mirror set, resulting in a single-partition volume set
and freespace, use the container unmirror
command. Note
that there is no equivalent command for a multilevel array of
mirror sets. To unmirror a multilevel array of mirror sets, use this
command for each underlying mirror set.
Syntax
container unmirror {container}
Parameters
{container}
Specifies the ID number (0 to 63) of the mirror set to unmirror.
You previously created the mirror set by using the
container create mirror
or container create
mmirror
command.
Examples
Before unmirroring a mirror set, use the container list
command to obtain information about any existing arrays. As the
following example shows, there is one existing array (array 0, a
mirror set) on this controller at the time the mirror set is
unmirrored:
AAC0>container list
Executing: container list
Num Total Oth Stripe Scsi
Dr Label Type Size Ctr Size Usage C:ID:L State
-- ----- ------ ------ --- ------ ------- -------- -----
0 Mirror 10.0MB NTFS 0:02:0 Normal
0:03:0
Note that the example eliminates some items in the container
list display so that you can see an example of the State column.
The following example shows how to unmirror a mirror set from
the mirror set that resides on SCSI device (0,3,0):
AAC0>container unmirror 0
Executing: container unmirror 0
Note that the example eliminates some items in the container
list display so that you can see an example of the State column.