Adaptec GDTSETUP Manual de instalación Pagina 76

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 93
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 75
76
Press <F2> to get detailed information of the Array Drive. If you think this flexibility
through to the end, you could add another RAID-1 Logical Drive to each Logical Drive
which is component of a RAID 4/5 Array Drive (double redundancy, but also double cost).
95HSODFH$UUD\&RPSRQHQW
If a Logical Drive of an Array Drive without a Hot Fix drive should fail (or is very likely to fail,
soon), you should replace the defective hard disk with a new one as soon as possible
because the Array Drive is without redundancy. The replacement Logical Drive has to have
at least the same capacity as the failed one. The replacement is carried out either interacti-
vely with GDTSETUP or online with the GDTMON utility program.
Vista de pagina 75
1 2 ... 71 72 73 74 75 76 77 78 79 80 81 ... 92 93

Comentarios a estos manuales

Sin comentarios