184
L. Appendix
L.1 Technical Data of the ICP Controller
Board Size Standard PCI long card format or 2/3 hereof
PCI Bus 32 Bit / 64 Bit 33MHz, 5 Volt
Weight 0,35 kg
Temperature Range in Operation
(measured in the enclosure)
10
O
to 55
O
C or 50
O
to 131
O
F
Temperature Range not in Opera-
tion
-10
O
to 60
O
C or 14
O
to 140
O
F
Humidity in Operation 20% to 75% not condensing
Maximum Altitude in Operation 3000 meter or approximately 10.000 feet
Power Consumption (5V, 12V) approximately 10 Watt
L.2 Boot Error Messages
Error Message possible cause, remarks
"Error detected on SIOP x" SCSI cable defective
hard disk connected defective
SIOP x defective
SCSI bus not properly terminated
termination power missing
"Memory error detected": Memory Module defective
Memory errors of the ICP Controller are also indicated acoustically with the audio alarm of
the ICP Controller (3 beeps repeated every 10 seconds).
The following audio alarm sequence indicates that the ICP Controller is tried to be oper-
ated without a DIMM: "beep-beep-short_pause-beep-beep-long_pause-beep-beep-
short_pause-etc.". All ICP Controller require a memory module for operation.