G Technical Specications
Environmental Specications
Note: Adaptec RAID controllers require adequate airow to operate reliably. The
recommended airow is 200 LFM (linear feet per minute), minimum. Forced airow
is required.
0 °C to 55 ° CAmbient temperature with forced airow
0 °C to 50 ° CAmbient temperature with Flash Backup Unit
10% to 90%, non-condensingRelative humidity
Up to 3,000 metersAltitude
Note: Ambient temperature is measured 1” from the RAID processor.
DC Power Requirements
RequirementsDescriptionBus Type
50 mV peak-to-peak (max)Ripple and noisePCIe
3.3 V ± 9%, 12 V ± 8%DC VoltagePCIe
Current Requirements
Typical CurrentAdaptec Model
0.17A @ 3.3 VDC; 1.25A @ 12.0 VDCAdaptec RAID 6405
0.17A @ 3.3 VDC; 1.25A @ 12.0 VDCAdaptec RAID 6445
0.17A @ 3.3 VDC; 1.25A @ 12.0 VDCAdaptec RAID 6805/6805Q
0.11A @ 3.3 VDC; 0.75A @ 12.0 VDCAdaptec RAID 6405E
0.125A @ 3.3 VDC; 0.80A @ 12.0 VDCAdaptec RAID 6805E/6805E R5
0.125A @ 3.3 VDC; 0.97A @ 12.0 VDCAdaptec RAID 6405T
0.125A @ 3.3 VDC; 0.97A @ 12.0 VDCAdaptec RAID 6805T/6805TQ
0.1A @ 3.3 VDC; 1.5A @ 12.0 VDCAdaptec RAID 7805/7805Q
0.1A @ 3.3 VDC; 1.6A @ 12.0 VDCAdaptec RAID 71605/71605Q
0.1A @ 3.3 VDC; 1.5A @ 12.0 VDCAdaptec RAID 71605E
0.1A @ 3.3 VDC; 1.8A @ 12.0 VDCAdaptec RAID 71685
0.1A @ 3.3 VDC; 1.8A @ 12.0 VDCAdaptec RAID 72405
105Proprietary and Condential to PMC-Sierra, Inc.
Document No.: CDP-00277-02-A Rev. A, Issue:
Serial Attached SCSI RAID Controllers Installation and User's Guide