ICP Storage Manager console, they may not really be deleted.
Reboot the controller; then, issue the ARCCONF DELETE command
again.
- On certain versions of Linux, you may see messages concerning font
conversion errors. Font configuration under X-Windows is a known
JVM problem. It does not affect the proper operation of the
ICP Storage Manager software. To suppress these messages,
add the following line to your .Xdefaults file:
stringConversionWarnings: False
- Some pop-up identification boxes include complete window frames
when running the ICP Storage Manager in bootable-CD mode.
These pop-ups may run off the side of the screen due to the
extra width of the window frame. This is a known problem of the
fvwm window manager on the CD.
- On rare occasions, the online help system may generate a Java
exception. This is due to a known problem in the HTML rendering
section of JFC/Swing.
--------------------------------------------------------------------
5. RAID Level-Specific Notes
5.1 RAID 1 and RAID 5 Notes
- During array migration from a RAID 1 or RAID 5 to a RAID 0, if
the original array had a spare drive attached, the resulting
RAID 0 retains the spare drive.
5.2 RAID 10 Notes
- You cannot change the priority of a RAID-10 verify. Setting
the priority at the start of a verify has no effect. The
priority is still shown as high. Changing the priority of
a running verify on a RAID-10 changes the displayed priority
until a rescan is done, then the priority shows as high again.
- Performing a Verify and Verify/Fix on an RAID 10 displays the
same message text in the event log, "Build/Verify started on
second level array of array 'Array_0.'" You may see the message
three times for a Verify, but only once for a Verify/Fix.
- During a migration from a RAID 0 to any redundant array like
RAID 5 or 10, ICP Storage Manager shows the status as
"Degraded Reconfiguring" for a moment, then the status changes
to "Reconfiguring." The "Degraded" status does not appear in the
event log.
5.3 RAID x0 Notes
- After building or verifying a leg of a second-level array, the
status of the second-level array is displayed as a "Quick
Initialized" array.
--------------------------------------------------------------------