The LEDs on the SSDs begin to ash.
4. Click Stop to stop blinking the SSDs.
5. Click Cancel to close the Locate maxCache window.
Working with Failed or Failing Disk Drives
This section describes how to use maxView Storage Manager to manage failed or failing disk drives in
your storage space.
Replacing Disk Drives in a Logical Drive
You can replace one or more disk drives in a logical drive. You may want to replace a drive to upgrade
to larger disk drives, or to make disk drive size uniform across the logical drive.
Caution: If another disk drive in the logical drive fails during rebuild (see Rebuilding
Logical Drives on page 113), you may lose data. For help solving disk drive problems,
see Recovering from a Disk Drive Failure on page 111.
To replace a disk drive in a logical drive:
1. In the Physical Devices tree in the Enterprise View, nd the disk drive you want to replace; note its
size and location (for instance Slot 1 in Enclosure 0).
2. Set the drive state to failed. (See Setting a Disk Drive to ‘Failed’ on page 78.)
3. Remove and replace the disk drive with one of equal or greater size.
4. Wait for the logical drive to rebuild. (See Rebuilding Logical Drives on page 113.)
5. Repeat these steps for each disk drive you want to replace.
Setting a Disk Drive to ‘Failed’
Before you can remove a disk drive, you should set it to a failed state to protect your data. You cannot
use maxView Storage Manager to set the drive state to Failed. You must use the Adaptec RAID Controller
Conguration command line utility (ARCCONF), to change the drive state. First, use the Storage Dashboard
to determine the drive's device ID and channel number on the controller (see Viewing Component Status
in the Storage Dashboard on page 90). Then, use the ARCCONF SETSTATE command to change the
drive's state to Failed. See the Adaptec RAID Controllers Command Line Utility User's Guide for details
about using ARCCONF.
You can set a disk drive to a failed state if:
• The disk drive is not part of a logical drive, or
• The disk drive is part of a redundant, healthy logical drive
78Proprietary and Condential to PMC-Sierra, Inc.
Document No.: CDP-00278-02-A Rev. A, Issue:
maxView Storage Manager User's Guide
Comentarios a estos manuales