Data transfer from the SIR-1000 Series to a PC
Recorded data from an AIT streamer drive to a PC
After data transfer, various analysis such as primary and secondary differentiation can also be performed.
AD converted incoming signals from the SIR-1000 Series to a PC in real time.The SIR-1000 Series as a high performance front end
■For SIR-1000 Series
●
Guard frame SHL-10
・Dimensions when mounted on the SIR-1000 Series:
352(W)×115(H)×356(D)mm
●
AIT tape
SDX1-25C (with memory)
●
Lithium ion battery pack
BP-L60A BP-L90A
●
Remote control unit SRM-10
●
Rack mount adapter
●
Battery charger
BC-L100
・Sequential charging of
up to 4 battery packs
●
Shock mount adapter
SSM-10
・Vibration: MIL-STD-810C
Method 514.2.2
Curve AR+H; 74-2000Hz
98.1m/s
2
(±10G)
●
Multi sync adapter
SSB-10
●
Sync cable SCK-10
●Stacking frame
For 64 channels : SHL-64
For 128 channels: SHL-128
●
Power supply unit SAA-24
・Power supply for SCX-32/32i
can supply up to 3 SCX-32/32i
,
s
●BNC cable length: 2 m, 1.5C-2V
PCBK21(BNC/BNC) PCBK28(BNC/BNC 8-cable set)
●SDX drive transfer package
SIR-1000 Series digital data /video interface options
※This photograph shows the SHL-10 mounted on the SIR-1000.
●
Carrying case
For SIR-1000 Series: STC-10
For SIR-1000 Series
+ Channel expansin unit: STC-23
■For SIR-1000/1000i
●
Channel expansion unit SCX-32
・Dimensions: 340(W)×60(H)×250(D)mm
・Weight: 3.5kg
*Direct voltage input only
■For SIR-1000W
●
Channel expansion unit SCX-16W
・Dimensions: 340(W)×60(H)×250(D)mm
・Weight: 3.5kg
For SCX-32: SDF-20
●
Differential input kit
For SIR-1000: SDF-10
SIR-1000 Series computer interface options
7
8
Options
For SIR-1000 Series:
SRT-10
For Channel expansion unit:
SRT-20
Can be used in
EIA standard 19" racks.
Shipping Case (STC-10R, STC-30R) is also available
・Display
・Control
・Interface
・Dimensions
・Weight
Bar meter (max. 16 channels), tape
address, input range, warning indicators
such as over range, etc.
REC, STOP, FWD, FF, REW, PAUSE, tape
speed, B/C mode, input range, ID No.
increment, search, etc.
RS-232C protocol
210 (W)×70 (H)×25 (D) mm
approx. 0.5 kg
:
:
:
:
:
Integrating the SIR-1000 Series with a Computer
Data transfer to a computer with a variety of interfaces to suit your system.
●SDX emulation board STB-10, PCscan III software: SUK-300
SIR-1000 series
Recorded data
SDX emulation board (STB-10)
(Mounted in the option slot on the rear panel of the data recoder)
(ADAPTEC ACK-W2W-E
recommended)
IBM-PC/AT or compatible machine
R
*
PC scan
software
SCSI host adapter
*
ADAPTEC
AHA-2940UW/U2W
PCI bus connection
*Not included in the package
Wide-SCSI cable
*
●AIT streamer drive(Stand-alone type SDX-S300C), PCscan III software: SUK-300
IBM-PC/AT or compatible machine
R
*
PC scan
software
SCSI host adapter
*
ADAPTEC
AHA-2940UW/U2W
PCI bus connection
*Not included in the package
Wide-SCSI cable
*
AIT streamer drive (SDX-S300C / stand-alone type)
(ADAPTEC ACK-W2W-E
recommended)
Recorded data
PCscan III is software for controlling the SIR-1000 Series from an IBM-
PC/AT or compatible. This software allows measurement data to be
transferred directly to the computer for data processing such as plotting
and analysis. Used together with a high-speed SCSI transfer board (STB-
30*), PCscan III allows the SIR-1000 Series to be used as a compact, high-
performance front end, making it possible to display waveforms on and
transfer data to a computer. Used together with an SDX SCSI emulation
board (STB-10) or an AIT streamer, PCscan III offers functions for
transferring and displaying recorded data and for exporting data to major
analysis software.
Computer
OS
CPU
Memory
Binary(Intel86), Binary(Motorola68),
ASCII-Eng(delim/comma), ASCII-Eng(delim/tab),
ASCII-Eng(delim/space), WAVE, DADisp, MATLAB,
Snap-Master (HEM), STAR, nVision(EZFile),
UDF58(Universal file)
〈Computer requirements〉
Specs in parentheses are for STB-30
:IBM-PC/AT or compatible machine
:WindowsNT4.0 or later, Windows95
:Pentium 266MHz or faster
(PentiumII 350MHz)
:64 Mbytes or more(128 Mbytes or more)
Interface
SCSI adapter
SCSI cable
Display
Floppy disk drive
Hard disk drive
:Wide SCSI-2 type
:AHA-2940UW/U2W by ADAPTEC
:ACK/WP-W2W-E by ADAPTEC
:800 ×600 dpi/256 colors or more
:3.5" 2HD/1.44 MB
:EIDE type, 5 Mbytes or more free space
〈Supported export formats〉
*There may be some restrictions in the data transfer through the STB-30 depending on the computer
,
s performance.
●High-speed digital I/O board (asynchronous type)SBS-10A
●High-speed digital I/O board (external sync type)SBS-10S
●Level converter SBS-LC1
Provides TTL/Bipolar interface for input/output
To be used with SBS-10A/10S
Maximum sampling frequency: 24 MHz/1 channel
Switchable between digital only or use
with 16 analog channels
Switchable to 1, 2, 4 or 8 channels
SDV-300PK
Consisting of:
・AIT streamer
(stand alone type)
・PCscan software
・Installation manual
SDV-N300PK
Consisting of:
・AIT streamer
(built-in type)
・PCscan software
・Installation manual
Maximum synchronous bit rate: 24 Mbps/1 channel
Synchronized to an external clock 90k∼24Mbps
Switchable to 1, 2, 4 or 8 channels
Switchable to internal or external sampling CLK
●High-speed SCSI transfer package STF-30PK
Consisting of:
・High-speed SCSI transfer board (STB-30)
・PCscan software
・Installation manual
●SDX SCSI emulation package STF-10PK
Consisting of:
・SDX SCSI emulation board (STB-10)
・PCscan software
・Installation manual
SCSI host adapter
*
PCI bus connection
*Not included in the package
SIR-1000 series
High-speed SCSI transfer board (STB-30)
(Mounted in the option slot on the rear panel of the data recoder)
(ADAPTEC ACK-W2W-E
recommended)
PC scan
software
ADAPTEC
AHA-2940UW/U2W
Wide-SCSI cable
*
IBM-PC/AT or compatible machine
R
*
Input signals
●High-speed SCSI transfer board: STB-30, PCscan III software: SUK-330
●Video board SVB-10
Television system: NTSC-M/ PAL-B, D, G, H, I, N
Data compression: MPEG2
Number of channel: ×1
Input/ Output connector: BNC
*Package using a built-in type drive also available.
*As to the combination of optional board,consult
your nearest distributor
R
R
●Channel expansion unit SCX-32i
・Dimensions: 340(W)×60(H)×250(D)mm
・Weight: 3.6kg
*ICP or Direct voltage input