Adaptec 2940U2W - Storage Controller U2W SCSI 80 MBps Manual de usuario Pagina 3

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 6
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 2
The SIR-1000 Series recorder can record video and measurement data
simultaneously on a single tape cartridge using optional video board,
SVB-10. The visual image played back on the video channel can be used
as complimentary analysis information in
analysing the measurement data.
Employing MPEG compression scheme
high quality picture can be recorded and
played back. Slow or fast replay is
possible by playing back at a different
tape speed from that of recording. Still
picture is also possible by pressing
PAUSE key. On input video format of
either NTSC or PAL can be selected
manually and video signal in the same
format as the input is played back.
3
4
Easy setup and monitoring
Highly resistant to vibration and shock
Wide bandwidth, multi-channels
Various option boards
Shock mount adapter SSM-10
Tape speed can be selected from a wide range of choices both on
recording and playback. During recording, for example, tape
speeds of 1
×
, 1/2
×
, 1/4
×
, 1/8
×
and 1/16
×
can be selected to
provide from 2 to 32 hours of recording time. Upon playback, long
recordings can be played back quicklyup to 16 times the
recording speed)to decrease data reproduction time or more
slowly than the recording speeddown to 1/16th the recording
speedto expand the data time base. Output filters are provided
for the whole bandwidth at any tape speed to smooth out the
reproduction waveform.
Time axis conversion
The PCM system provides a dynamic range of 80 dB or more
(SIR-1000/-1000ithrough 16-bit linear quantization and independent
AD/DA conversion for each channel. This not only allows extremely
accurate data recording but also facilitates the input range settings.
In addition, the adoption of 64 × oversampling digital filters provides
nearly linear phase characteristics and achieves an inter-channel
phase difference of less than 1 degreeSIR-1000/SIR-1000i). The
analog input level has an allowable range of up to 133% of the full
scale range setting. The analog characteristics specified in this
data sheet are for up to 133%. And the input DC offset can also be
adjusted within the range of ±100%. The analog output level can be
selected from ±1 Vpk, ±2 Vpk or ±5 Vpk calibrated output, or
from ±0.5 to 5 Vpk continuous variable output.
High-grade recording and playback
The cartridges use the newly
developed AMEAdvanced Metal
Evaporatedtape which features
superior output characteristics,
reliability and durability. The SIR-
1000 Series' real-time verify-rewrite
function reads the data written on
the tape during recording and
rewrites the data at once if errors
occur. This reduces data dropout to
virtually zero and greatly improves
data integrity. Furthermore, the SIR-1000 Series is equipped with an
active head cleaner that automatically detects and cleans the heads
to keep them constantly clean even when the SIR-1000 Series is used
outdoors.
The main unit has a built-in, large-capacity buffer memory
enabling pre-trigger data of 3 secondsnormal speedto be
recorded on tape. This allows reliable recording of unpredictable
events and transient signals.
Pre-trigger recording
Care has been taken to ensure easy operation during multi-
channel, on-site measurement.
16-channel bar meter display : The incoming signal level for
16 channels is displayed on a backlit LCD panel with a wide
viewing angle for high visibility outdoors and in dark locations.
The display can be switched to match the measured phenomenon
such as decibel(dB)for noise and vibration and percentage(%)for
stress and distortion.
Test signals(internal or external) : Four types of test signals(±
100% AC sine wave, 100% DC, 100% DC and 0Vare stored as
digital data and can be used as highly accurate reference signals
for the analog channels. Users can also input a reference signal
from an external source to channel 1 for distribution to all
channels as a reference signal.
Calibration : The analog channel DC offset and gain can be
calibrated.
Auto range/auto offset : The analog channel input range can
be set and the input offset canceled automatically.
●Setting for all channels : Parameters for all channels can be
set by pressing one key.
High-speed tape search : This function allows rapid access to
target data stored on the tape. Also, storing the Table of Contents
ID and tape address informationin the Memory-In-Cartridge
allows even higher speed searches.
Self check : The self diagnostic check can be performed to
ensure the operations.
In addition to the key switches on its front panel, the SIR-1000 Series
can be controlled from the SRM-10 dedicated remote controller
option, RS-232C port, or relay contact port. The SRM-10 is a
highly functional remote controller with an LCD display panel
identical to that on the recorder main unit, including a 16-channel
bar meter display. The SRM-10 allows remote monitoring of the
recording setup information, tape address information and other
information. The RS-232C port is used when controlling the
recorder from a host computer, and the relay contact port is used
with TTL level external signals. Furthermore PCscan III software
with STB-30 can control via SCSI.
Versatile control functions
The SIR-1000 Series operates on AC 100/120 V 90 to 132 V, 47 to
440 Hz, AC 220/240 V198 to 250 V, 47 to 66 Hz, or external DC
12 V11 to 30 Vpower source. Also large-capacity lithium ion
battery pack can be mounted on the data recorder for convenient
use outdoors. AC can be backed up by external DC or the battery
pack, and external DC can be backed up by the battery pack to
allow uninterrupted recording of valuable data.
The SIR-1000 Series has dimensions of 340 (W) × 115 (H) × 260 (D)
mm and weighs approximately 7.5kgSIR-1000, 7.6kgSIR-1000i,
7.7kgSIR-1000W basic configuration, giving it the best
portability and space factor of any data recorder in its class. In
addition, the SIR-1000 Series tough-durability is assured by the use of
strong cast aluminum in the unit
,
s casing and steel frame
construction for your difficult field environments.
Small, lightweight and rugged
Option slots are provided on the rear panel of the recorder for
mounting option boards.
SBS-10A/10S bit serial boards : These option boards are used to
input and output a max of 24Mbps digital data.
STB-10/30 SCSI interface boards : These option boards are used 
to perform high-speed SCSI transfer of digital data to and from a
host computer.
→ See“Integrating the SIR-1000 Series with a Computer”for details.
SVB-10 video board : This option board is used for recording
and replaying video signal.
The SBS-10Aasynchronous, option and
SBS-10Sexternal sync, optionbit stream
boards are provided for recording and
playback of high-speed digital data in
applications such as telemetry and
monitoring digital network. The SBS-10A
or SBS-10S is mounted in one of the option slots on the rear panel
of the SIR-1000 Series. 
Digital data can be recorded either alone or together with analog
data. In addition to the functions the SBS-10A offers, the SBS-10S
can synchronize the recorder with external clock up to 24 MHz
and can record digital data at any desired bit rate by using
variable buffer memory. The number of high-speed digital channels
can be switch-selected to 1, 2, 4 or 8-channel mode.
High-speed digital data recording
Video recording
In addition to the analog data channels, the SIR-1000 Series main
unit is equipped with auxiliary channels as standard, allowing
other useful information and data to be recorded and played back
along with the main analog data.
AUX-1(serial digital channel : tacho pulse, etc.
AUX-2(analog channel : IRIG-B time code signals, etc.
IRIG-B time code calibrates the recorder
,
s internal clock.
Voice channel : voice annotations
Convenient auxiliary channels
The number of channels for the SIR-1000/SIR-1000i can be
expanded up to 128 16 channels for SIR-1000Wand 2 hour
recording is possible regardless of the channel configuration.
Synchronous recording and play back up to 8 units are also
possible using an optional SSB-10, Multisync adapter.
●SIR-1000/SIR-1000i The SIR-1000/SIR1000i in basic configuration
features a 20kHz bandwidth for all 16 channels. In addition, 32
channels of DC to 20kHz analog data can be simultaneously
recorded on a single data cartridge by combining the recorder
with an optional SCX-32/SCX-32i Channel Expansion Unit. The
number of channels can be further increased by adding channel
expansion units. 128 channels of 5kHz analog data can be recorded
with a system consisting of the SIR-1000/SIR-1000i and seven
SCX-32/SCX-32i
●SIR-1000W :The SIR-1000W is capable of recording 4 channels
of DC to 160kHz or 8 channels of 80kHz analog data. With an
optional SCX-16W Channel Expansion Unit the number of
channels is expanded to 16 for the bandwidth of 40kHz. 
→ See “Supporting the Multi-channel operation”for details.
SIR-1000Rear)
SIR-1000+SCX-32 Combine frame
The SIR-1000 Series can perform
normal recording even when
exposed to vibrations of ±14.7m/s
2
(±
1.5G, 6 to 200Hz. For applications
under harsher vibration or shock,
the shock mount adapter which
can absorb a shock of 98.1m/s
2
±10G, 74∼2000Hzmay be used
to ensure reliable recording.
Alternative power sources
Vista de pagina 2
1 2 3 4 5 6

Comentarios a estos manuales

Sin comentarios