Appendix D: Using the Array Configuration Utility for DOS 102
# Clear the array (don’t build/verify it)
Method=Clear
# Don’t wait for clear to complete
Wait=No
# Use drives 0, 1, 2
Drives=0:0:0, 0:1:0, 0:2:0
End
Sample Script for SATA Controllers
This is a sample ACU file that will initialize all disk drives connected to the SATA controller
and create a RAID 5 array with the disk drives on ports 0, 1, and 2.
Array=MyData2
Type=RAID5
Size=Maximum
InitializeAll=Yes
Method=Build/Verify
Wait=No
Drives=0:0:0, 0:1:0, 0:2:0