so ASPI MS-DOS Manager with ASPI Disk Module Version 3.0 PIN: 472800-01 Rev - B
Section One Introduction to support programs that use virtual memory (i.e., MS Windows 3.0, MS Windows 386, Quarterdeck QEMM 386, Qualitas 386MAX) to
Section One Introduction Ifonly a total of two or less hard drives is in the system <e.g., two stan-dard hard disks, one standard hard disk and one
Section One Introduction This page intentionally left blank. ASW-1410 Ver. 3 1-4 adoptee
Section Two Installation The first installation step is to copy the files from the ASW-1410 program diskette to a directory on drive C using the-DOS C
Section Two Installation When the driver is loaded, the display should look similar to: AHA-1540/1542/1640 ASPI Manaoer for DOS Version 3.0 Copyrloht
/L Section Two /P <port address> /S<slot number> /D /W ASW-141O Ver. 3 Installation Sets the port address that the driver uses to communic
/V Section Two Installation /WM This option has the same function as the /W option except that this will always allocate the 64K virtual buffer from
II Section Two Installation IN<bus on time> IF<bus off time> Five values are predefined: 00 - 5.0 MB/sec (i.e.,/XOO) 01-6.7 MB/sec 02
Section Two Installation /NORST This option will cause the driver to not issue a hard reset to the host adapter during initialization only if the BI
Section Two Installation COMMAND LINE OPTIONS The following command line options may be added to the ASPIEOOS.SYS driver to change the parameters of t
Section Two Installation ASPIDISK.SYS INSTALLATION In order for the ASPIDISKSYS driver to recognize logical drives partitioned with AFDISK, the CON
Section Two Installation If you add the '/D' command line option to both drivers (i.e. , DEVICE = ASPI400s.5YS /D DEVICE =ASPIDISK.SYS /D)
Section Two Installation To invoke AFDISK, simply type AFDISK at the OOS prompt. Currently three slash options are available with AFDISK. These are:
Section Two Installation The displayed list shows all installed SCSI disk drives, including remov-able media devices. The "HAN" field ind
Section 1\vo Installation The existing partitions on the drive will be displayed on the upper right-hand comer of the screen. Both DOS and non-DOS pa
Section Two Installation When the desired cylinder numbers have been entered, press the <Esc> key. The screen will look similar to: Adaptec Di
Section Two Installation A drive that was installed with the host adapter BIOS cannot be parti-tioned with AFDISK. If such a drive is selected, the fo
Section Three Software Considerations Some programs that use the virtual mode of the 386 sometimesrequire a virtual buffer allocated to run correctly
Section Three Program 386MAX by Qualitas MOVE'EM· by Qualitas Any protected mode Software (No VDS support) Any protected mode· Software
Section Four Using Multiple Host Adapters The ASPI400s.SYS and ASPIEOOS.SYS drivers will support multiple host adapters. Support for multiple host ad
adoptee ASW-1410 Ver. 3 ASPI DOS Manager with ASPI Disk Module Installation Guide
Section Four Using Multiple Host Adapters The host adapter at port address 330 will be assigned to HA #0, and the host adapter at port address 334 wil
Section Four Using Multiple Host Adapters AHA-1740 Standard Mode: When the AHA-1740 is in Standard Mode, the ASPI4DOS.SYS driver should be used. Multi
Section Four Using Multiple Host Adapters This page intentionally left blank. ASW-141O Ver. 3 4-4 adoptee
Section Fi.ve Commonly Asked Questions Q. What is VDS? A. VDS stands for virtual DMA Services. It is a standard, developed so that bus master devi
Section Five Commonly Asked Questions Q. What are the DOS partition limits with my SCSI host adapter? A. The maximum 005 partition size is determi
Section Six Error Messages ASPI4DOS.SYS Invalid entry for 'Ip' setting You have entered an invalid'IP' setting on the command lin
Section Six Error Messages Unable to set Bus Master transfer rate The driver failed in its attempt to set the host adapter's Bus Master DMA trans
Section Six Error Messages Not enough memory available to load driver This error only occurs with DOS 5.0 and above. This message will only be display
Section Six Error Messages ASPIDISK.SYS No SCSI logical drives to support. This indicates that ASPIDISK has not found any logical drives to support. T
Section Six Error Messages Failed to read, or invalid, boot record. This messgae will appear if ASPIDISK was unable to read data from a disk, or if th
I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I II I I I I II II II I I I
Section Six Error Messages This page intentionally left blank. ASW-1410 Ver. 3 6-6 adoptee
Stock No.: SfOI68..(() Rev. Aadaptee TH 7/91691 south milpitas blvd.• milpitas. ca 95035 • (408) 945-8600 Printed In Singapore
Preface COPYRIGIIT Copyright 1991 Adaptec, Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or t
Table of Contents 1.0 INT'RODUCTION ... 1-1 ASPI J)()S MANAGE
This page intentionally left blank. ASW-1410 Ver. 3 ii adaptee
Section One Introduction This document provides installation infonnation on Adaptec's Advanced SCSI Programming Interface (ASPJ) DOS Manager for